In many applications the
set-value of the concentration of a chemical product in a solution
shall be achieved in spite of different disturbance factors. This is
very important for
example in professional dishwashing:
if the concentration of the detergent is too low, the hygienic
requirements are not achieved. If the concentration is to high, the machine
isn't operating economically and dishes made of plastics and metal can even
be destroyed. |
|
|
Here the
conductivity-controllers are a good choice: conductivity-sensor either with
conductive or inductive principle measures the electrical conductivity in
the washing water. As the normally used detergents because of their chemical
contents have high conductivity-values, the measurable electrical
conductivity is proportional to the concentration of the detergent in the
washing water. if the concentration of the detergent decreases because of
the dirty dishes or because of additional fresh-water, the electrical
conductivity, measurable at the sensor decreases as well. The
conductivity-controller recognizes the change and initiates a dosage of
detergent. So the set-value is achieved again. |
|
| A complete controller-system exists of a conductivity-sensor, a
conductivity-controller and a controlled equipment like a pump for dosing
the electrical conductible product. In the following table you find combined
devices, where a peristaltic pump is controlled by a microprocessor-based
conductivity-controller in a single housing. |
|
Model |
Compact L plus |
DSP 9630 mcs |
Concept 2114 / 2115 |
Concept 2105 / 2106 |
|
|
|
 |
 |
 |
 |
 |
|
applications |
glas-, Hauben- and small
Korbtransport- and small conveyor
machines |
glas-, pass-through- and small
/ medium rack conveyor washers |
glas-, pass-through and small
to big conveyor washers |
gläs-, pass-through and small to big conveyor
washers |
package-drum and bottle-washers |
|
rate of delivery [ml/min] |
100 |
166 |
150 (250) / 500 |
150 (250) / 500 |
833 |
|
Max. dosage quantity [ml/h] f.e. basic filling
of machines |
6.000 |
2.500 |
9.000 / 12.000 |
9.000
/ 12.000 |
25.000 |
|
recommended max.
dosage-rate (long-term operation) [ml/h] |
6.000 |
2.500 |
5.000 (7.500) / 12.000 |
5.000 (7.500) / 12.000 |
25.000 |
|
range of conductivity [mS/cm] |
0,5 -12
0,5 - 25 (alternativ) |
0,5 - 25
15 -120 (alternativ) |
0,5 - 25 15 - 120 (option) |
0,5 - 25 / 15 - 150 |
0,5 - 25
15 - 120 (option) |
|
principle of measurement |
conductive |
conductive |
conductive |
inductive |
conductive or inductive |
|
recommended sensor |
EE 10-3/8
(shipped with device) |
EE 65-25-10 |
EE 65-25-10 |
ILFS 02
|
EE 65-25-10 or
ILFS 02 or ILFS02-TK2 |
|
surveillance of process-errors |
dosage
time surveillance |
dosage
time surveillance |
dosage
time surveillance |
dosage
time surveillance |
dosage
time surveillance |
|
process
visualisation |
1 LED |
2 LEDs |
3 LEDs |
3 LEDs |
4 LEDs |
|
detection of damaged pump tube |
yes |
yes |
yes |
yes |
4 LEDs |
|
package-drum-empty-surveillance |
- |
- |
yes |
yes |
4 LEDs |
|
external
warning signal (output) |
- |
- |
yes |
yes |
yes |
|
time-controlled basic dosag (for
filling of machines with fresh water) |
- |
- |
yes |
yes |
yes |
|
wall-thickness of pump tube |
1,6 mm |
1,6 mm |
2,4 mm |
2,4 mm |
2,4 mm |
|
pump tube (standard) |
PS 140 PH |
PS 140 PH |
DPSN 136-4,8x2,4 PH / PS 136-6,4x2,4 PH |
DPSN 136-6,4x2,4 PH / PS 136-6,4x2,4 PH |
PS 230-6,4x2,4 PH |
|
tube retainer system |
9911 |
8811 |
9911 |
9911 |
9310 |
|
tube connector for assembled
tubes |
5 x 1,5 mm |
6 mm |
6 mm (4 mm) |
6 mm (4 mm)
/ 6 mm |
8 mm |
|
dimensions in mm (B x H x T) |
65 x 135 x 82 |
170 x 150 x 90 |
94 x 170 x 130 |
94 x 170 x 130 |
320 x
190 x 93 |
|
mounting dimensions (B x H) |
120 |
188 x 88 |
67 x 100 |
67 x 100 |
238 x 130 |
|
article-number |
10090 |
10070 |
10086 / 10091 |
98235 / 98267 |
10087 |